XLMTRACE SELF-REGULATING HEATING CABLE
The heating element in the XL-Trace heating cable consists of a continuous core of conductive polymer extruded between two copper bus wires. The XL-Trace heating cable regulates its power output in response to pipe temperature changes. This self-regulating technology allows XL-Trace heating cable to be overlapped or installed on plastic pipes ... Read More
R XL-Trace Self-Regulating Pipe Freeze Protection System
XL-Trace heating cable regulates its own heat output in response to pipe temperature changes. This self-regulating feature eliminates hot spots and results in better tem-perature control and exceptionally long cable life. More than 300 million feet of Raychem self-regulating heating cable have been installed worldwide since 1970. Low total ... Get Content Here
HWAT System - A Manufacturer's Representative Of Heating ...
Raychem ® HWAT® Systems must 2.1 Heating Cables The HWAT System includes HWAT-Y2 and HWAT-R2 heat- • Walk the system and plan the routing of the heating cable on the pipe. • Inspect the piping and remove any burrs, rough sur-faces or sharp edges. ... Document Viewer
Heat Trace Design Guide - ARCO Engineering
The system, including heating cable, connection accessories, and temperature controls. Thermal Design - Pipes:. . 1 TABLE OF to determine the heat loss from each pipe or tank to be traced. Collect the following data for each pipe (for tank applications go to page 6). Then fol- ... Get Document
Self-Regulating Heating Products - University Of Arizona
The self-regulating design of Raychem heating cables eliminates worry about overheating or burnouts from overlapping. The conductive polymer core automatically adjusts heat output 120-V and 240-V heating cable Pipe runs up to 100 feet, up to 21/ 2 inches in diameter ... View Doc
SELF-REGULATING HEATING CABLE FOR PIPE FREEZE PROTECTION
RAYCHEM ETL can be designed on site and cut-to-length unlike constant wattage heater cables. The heating cable is simply terminated with an end seal at the end of the pipe run. ... Fetch Full Source
Heat Cable Splice Kit Tutorial - YouTube
Connecting a Self-Regulating heat cable to a power connection cable with a water tight heat shrink system and finalizing the cable with a heat shrinkable end seal PVC Pipe Bending - Duration ... View Video
Industrial Heat-Tracing Installation And Maintenance Manual ...
Industrial Heat-Tracing Installation and Maintenance Manual secure the heating cable on the the pipe: GT-66 or GS-54 fiberglass tape, or AT-180 aluminum tape. Raychem approved tapes. 3 Heating Cable Installation. 8 Attaching the heating cable ... Fetch Document
Installation Instructions And User Guide For The Frostex Pipe ...
How many straight runs of Frostex heating cable required to protect the pipe. One run is equal to the length of the pipe. • To minimize the amount of heating cable required, select the optimal insulation thickness from Table 1 or Table 2. Cable Length Selection Tables Table 1. Metal Pipe Number of heating cable runs required 1/2" 1 1 2 21/2" ... Read More
XL-Trace System - Nventthermal.com
RAYCHEM XL-Trace self-regulating heating cables and connections for commercial construction pipe systems in ordinary (nonhazardous) areas. The manual covers Support Additional heating cable Pipe hangers (insulated) No additional heating cable Pipe hangers noninsulated and U-bolt supports: ... Doc Viewer
SPECIFICATION GUIDELINE - Raychem Trace Heating Cables
SPECIFICATION GUIDELINE . XL-TRACE LSZH SYSTEM . PIPE FREEZE PROTECTION . GENERAL . All insulated pipes exposed to risk of freezing shall be fitted with an energy efficient self-regulating trace heating system, known as Raychem XL-Trace, manufactured by Pentair. ... Fetch Doc
120 V Preassembled Electric heating Cables For pipe Freeze ...
120 V preassembled electric heating cables for pipe freeze protection and roof & • Raychem H913/H914 Roof Clips (10 clips for each 7 linear feet of the installation of Gardian heating cable for pipe freeze protection and must be followed. ... Retrieve Full Source
Heat-shrink Tubing - Wikipedia
Heat-shrink tubing (or, commonly, The tubing is then shrunk to wrap tightly around the joint by heating in an oven or with a hot air gun or other source of hot gas flow. Heat-shrink tubing was invented by Raychem Corporation in 1962. ... Read Article
In-pipe - Nventthermal.com
Estimating the Length of Heating Cable Required For all Raychem In-Pipe Heating Cables, measure the pipe length while allowing for the contour of the land. For In-Pipe Mini, the heating cable can be up to 6 in (15 cm) shorter than the pipe. For In-Pipe Miser and In-Pipe Retro, the cable must be 1 ft (30 cm) shorter than the pipe. ... Access Full Source
Trace heating - Wikipedia
Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels.Trace heating takes the form of an electrical heating element run in physical contact along the length of a pipe. The pipe is usually covered with thermal insulation to retain heat losses from the pipe. ... Read Article
Low Smoke Zero Halogen - Wikipedia
Low smoke zero halogen or low smoke free of halogen (LSZH or LSOH or LS0H or LSFH or OHLS) is a material classification typically used for cable jacketing in the wire and cable industry. LSZH cable jacketing is composed of thermoplastic or thermoset compounds that emit limited smoke and no halogen when exposed to high sources of heat. ... Read Article
Commercial & Residential Self-regulating Heating Products
Raychem commercial and residential self-regulating heating products are the ideal solution for pipe freeze protection, roof and gutter de-icing and crankcase heating applications. These products in-clude WinterGard, WinterGard Plus and WinterGard Wet cut-to-length heating cable systems, Gardian preassembled heating cables and FreezGard crank- ... Document Retrieval
XL-Trace System For Fire Sprinkler Freeze Protection Design ...
XL-Trace® System for Fire Sprinkler Freeze Protection The Raychem ® XL-Trace cable utilizes • The heating cable is protected from the pipe to the power connection box in UL Listed and CSA Certified water-sealed c onduit (minimum 3/4-in ch diameter) suitab le for the location. ... Retrieve Content
Self-Regulat- Cables BTV SELF-REGULATING HEATING CABLES
Heating cable construction Product overview The BTV family of self-regulating heating cables provides the solution to freeze-protection and process-temperature maintenance applications. BTV heating cables maintain process temperatures up to 150°F (65°C) and can withstand intermittent exposure to temperatures up to 185°F (85°C). ... Doc Retrieval
WinterGard H911 120-V Plug-in Power Connection Kit
The WinterGard H911 120-V Plug-In WinterGard H311 pipe heating cable • Easy installation • Built-in ground-fault circuit protection • Push-on gel-filled Raychem Standard Terms and Conditions of Sale for this product, and in no case will ... View Full Source
WinterGard Power Connection Kit With End Seal
• Review the WinterGard heating cable design and compare to materials received to verify that the proper WinterGard heating cable and accessories are available. The WinterGard heating cable will have the heat-ing cable type printed on the outer jacket. •Walk the system and plan the routing of the WinterGard heating cable on the pipe. 2. ... Fetch Document
Heat cable Testing - YouTube
How to properly test a pipe heat cable. You will not need the candy thermometer. Warmup Pipe Freeze Protection Heating Cable - Duration: 7:31. A Concord Carpenter / ToolBoxBuzz 14,718 views. 7:31. ... View Video